[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Motion: Clarify convert-to-signed, convert-to-unsigned, clamp-to-signed, clamp-to-unsigned



        This is item 16 on the July agenda.  - Dan

Subject: Motion: Clarify convert-to-signed, convert-to-unsigned, 
clamp-to-signed, clamp-to-unsigned
Date: Thu, 22 Jun 2006 12:08:48 -0700
From: "James, David V" <david.v.james@xxxxxxxxx>
To: "David Hough 754R work" <754r@xxxxxxxxxxx>, <stds-754@xxxxxxxx>

Background:
The first attempt to revised the brief conversion text in the draft
has led to a raft of questions. To address these questions in detail,
a specific table (rather than abstract reference to a rounding table,
with "similar" rounding) is needed. Such tables are provided.

Rather than fixing this problem in adhoc ways and introverted rules,
listing the specific rounding results is needed.

As always, editorial reviews can fix-up the text, if
ambuiguities or nontechnical errors are discovered.

I understand this is late-coming, but feel this a better/complete
solution when compared to hastily generated text patches.


Motion:

Incorporate pages 51-to-58 of:
  http://dvjames.com/esync/FloatTables2006Jun22.pdf
Where the result of conversions to integer are listed in a clear
and exact fashion. 