Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [8023-10GEPON] power saving Ad-hoc



 
Dear Suzuki-san, 
Indeed You're correct. 
100BASE-T for GPON and EPON 
1000BASE-T for 10G-EPON
Please update the table as necessary. 

PS. I am not Jeff :) 

Marek Hajduczenia (141238)
NOKIA SIEMENS Networks S.A. 
System Architect - COO BBA DSLAM R&D

Rua Irmãos Siemens, 1, Ed. 1, Piso 1
Alfragide, 2720-093 Amadora, Portugal

* marek.hajduczenia@xxxxxxx
(+351.21.416.7472  4+351.21.424.2337

-----Original Message-----
From: ext Ken-Ichi Suzuki [mailto:kenyichi@xxxxxxxxxxxxxx] 
Sent: quarta-feira, 23 de Julho de 2008 2:04
To: STDS-802-3-10GEPON@xxxxxxxxxxxxxxxxx
Subject: Re: [8023-10GEPON] power saving Ad-hoc

Dear Jeff,

Thanks for your effort.
I'd like to confirm the definitions of "UNI-Ethernet" in your table.
I think you means UNI-Ethernet's for G-PON and EPON as 100BASE-TX and 
"UNI-Ethernet" for 10G-EPON as 1000BASE-T.  Is that right?

Best regards,
Ken-Ichi

At 2008/07/22 23:23 Hajduczenia, Marek (NSN - PT/Amadora) wrote:
> Dear Otaka-san, 
> As a kick-start of the discussion, I collected some information from the data sheets I have access to. Company names are obviously excluded from the file. 
> I managed to collect 1 GPON class ONU power consumption figures, 2 more restricted sets for EPON and two estimated power consumption sets for 10/1GEPON class system. It would be nice if this document gets extended with time, with people introducing values they feel comfortable with and which can be confirmed. Please note that the values I included in the table are for discrete component systems and are worst-case ones. SoC designs can have much power consumption figures (I saw data sheets for 2 W ONU units, though it is hard to estimate consumption of individual ONU elements in such a case.)
> Any comments, please let me know. 
> regards
> 
> Marek Hajduczenia (141238)
> NOKIA SIEMENS Networks S.A. 
> System Architect - COO BBA DSLAM R&D
> 
> Rua Irmãos Siemens, 1, Ed. 1, Piso 1
> Alfragide, 2720-093 Amadora, Portugal
> 
> * marek.hajduczenia@xxxxxxx
> (+351.21.416.7472  4+351.21.424.2337
> 
> -----Original Message-----
> From: ext Akihiro OTAKA [mailto:ootaka@xxxxxxxxxxxxxx] 
> Sent: domingo, 20 de Julho de 2008 11:12
> To: STDS-802-3-10GEPON@xxxxxxxxxxxxxxxxx
> Subject: [8023-10GEPON] power saving Ad-hoc
> 
> Dear all,
> 
> This is Akihiro Otaka.
> As announced by the chair, we formed the power-saving
> ad-hoc in the July meeting.
> If you are interested in this ad-hoc, please contact
> me.
> 
> Our objectives are following;
> 1) Quantify typical power consumption of various
>   units/functions in ONU and OLT.
> 2) Propose solution(s) and quantify potential power
>   savings of each solution and cost impacts.
> 3) Quantify the impact on service delivery and QoS
>   of various solutions.
> 
> I'd like to start with item (1),
> to study what kind of power-saving (which part should
>   be power-saved) is effectve in the PON system.
> And any contributions are appriciated.
> 
> Best regards,
> Akihiro Otaka. (NTT)


-- 
Ken-Ichi Suzuki
NTT Access Network Service Systems Labs.
E-mail:kenyichi@xxxxxxxxxxxxxx
Tel:+81-43-211-3189/Fax:+81-43-211-8250