Re: [802.3_4PPOE] 57V



Dan -

I’d prefer:

"Type 1 and Type 2 PDs shall withstand any voltage from 0V to 57V at the PI indefinitely without permanent damage.

Type 3 and Type 4 PDs shall withstand any voltage or combination of voltages from 0V to 57V across any combination of Mode A and Mode B conductor pairs (defined in Table 33-13) indefinitely without permanent damage.

These tests shall be run with the two conductors of each tested pair tied together.”

This preserves the ambiguous text from AT for Types 1 and 2 while making Types 3 and 4 clear and stopping the across-a-pair problem.

Dave


> On Jul 15, 2015, at 8:55 PM, Dan Dove <dan.dove@xxxxxxxxxxxxxxxxxx> wrote:
> 
> Here is a proposed language regarding 57V.
> 
> Feel free to respond, add, change as appropriate.
> 
> 
> <iihfbecf.png>
> Dan Dove
> Chief Consultant
> Dove Networking Solutions
>