Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [802.3_4PPOE] Issue with the state machine



Hi Yair,

 

The existing logic is intentional.  The idea is that you should only end up in IDLE_PRI if there is an error condition or power is intentionally removed from the primary alternative…..in which case, you should exit back to Main IDLE unless power is applied to the secondary alternative.

 

Thanks,

Chris

 

From: Yair Darshan [mailto:YDarshan@xxxxxxxxxxxxx]
Sent: Sunday, October 29, 2017 5:44 AM
To: Picard, Jean <jean_picard@xxxxxx>; Chris Bullock (bullock) <bullock@xxxxxxxxx>; Dylan Walker (dylanwal) <dylanwal@xxxxxxxxx>
Cc: Yair Darshan <YDarshan@xxxxxxxxxxxxx>; STDS-802-3-4PPOE@xxxxxxxxxxxxxxxxx
Subject: Issue with the state machine

 

Hi guys,

I find issue here, please verify.

Thanks

Yair

---------

From IDLE_PRI to START_DETECT_PRI (145.2.5.7, Page 141 line 10)

Comment

The condition:           !pwr_app_pri * pwr_app_sec           doesnt make sense that only if the secondary is powered we can  go to START_DET_PRI.

 

pwr_app_pri

pwr_app_sec

START_DET_PRI

0

0

0

0

1

1

1

0

0

1

1

0

The conditions should allow to move to START_DET_PRI in the following conditions:

a)      !pwr_app_pri OR

b)      !pwr_app_sec

i.e. the condition should be: !pwr_app_pri + !pwr_app_sec          

pwr_app_pri

pwr_app_sec

START_DET_PRI

0

0

1

0

1

1

1

0

1

1

1

0

Proposed remedy:

!pwr_app_pri * pwr_app_sec          

To: !pwr_app_pri + !pwr_app_sec          

 

 

Darshan Yair

Chief R&D Engineer

Analog Mixed Signal Group

Microsemi Corporation

 

1 Hanagar St., P.O. Box 7220
Neve Ne'eman Industrial Zone
Hod Hasharon 45421, Israel
Tel:  +972-9-775-5100, EXT 210.

Cell: +972-54-4893019
Fax: +972-9-775-5111

 

E-mail: <mailto:ydarshan@xxxxxxxxxxxxx>.