Mikael,

> I see more reason for a 40G optical standard that basically extends
> the OC192 10GE WAN PHY standard to OC768 as this would enable
> ethernet to be carried in current state of the art DWDM systems. 

FYI, this standard exists for some time within ITU-T Recommendations.
Refer to http://www.ieee802.org/3/hssg/public/sep06/vissers_01_0906.pdf 
for an introduction.
The frame format is shown in slide 8. 

The applicable ITU-T Recommendations are listed on slide 16; for an 
STM-256/OC-768 interface carrying Ethernet MAC frames those are:
- G.8012 Ethernet UNI and Ethernet NNI
  http://www.itu.int/rec/T-REC-G.8012/en
- G.7041 Generic framing procedure (GFP)
  http://www.itu.int/rec/T-REC-G.7041/en
- G.707 Network node interface for the synchronous digital hierarchy (SDH)
  http://www.itu.int/rec/T-REC-G.959.1/en
- G.959.1 Optical transport network physical layer interfaces
  http://www.itu.int/rec/T-REC-G.707/en
- G.693 Optical interfaces for intra-office systems 
  http://www.itu.int/rec/T-REC-G.693/en.


> This would of course be a moot point if we think that most DWDM
> vendors will have a 100GE DWDM transponder by the time the 100GE
> standard is ready, and a 40GE OC768 compatible standard would take
> the same amount of time to implement as the 100GE variant.

Carrying 40GE within a STM-256/OC-768 signal allows to deploy today's 
available 40G DWDM transponders. As such only a the STM-256/OC-768 
compatible 40GE interface card within the Ethernet Switches or IP/MPLS 
Routers is still required. With all standards available and existing 
STM-256/OC-768 framer as well as Ethernet into GFP mapper devices 
available, it is jsut the combination into a signle STM-256/OC-768 based 
40GE device that is missing. As its design can start today, it could be 
available soon, certainly before a 100GE design would be available.


> I do think that it should be taken into account that a 100GE standard
> will be carried over DWDM, and mechanisms should be implemented for 
> fast-failure-detection, mostly of the "there is a one-way fiber 
> break"-variant 

G.709 compliant DWDM systems/networks include such fast-failure-detection 
mechanism as well as a means to signal such fault to the connected system; 
i.e. the clause 16.6.1/G.709 "generic-AIS" mechanism. The generic-AIS 
signal is a signal with a 2047-bit polynomial number 11 (PN-11) repeating 
sequence.
http://www.itu.int/rec/T-REC-G.709/en
For STM-256/OC-768 based 40GE interfaces these fast-failure-detection and 
signalling mechanisms are defined and will be available in designs of 40GE 
itnerface ports and are available in associated 40G transponders.

> and the "the BER is high so the link is not good".

The STM-256/OC-768 based 40GE formats include BER detection capabilities 
via the B2 and B3 bytes in the frame. It furthermore includes a BCH-3 FEC.

Regards,
Maarten
PS. There is an alternative 40GE interface standardised in ITU-T 
recommendations; this is the OTM-0.3 based 40GE interface using the G.709 
(OTN OTU3/ODU3, see slide 9) frame instead of the G.707 (SDH/SONET 
VC-4-256c/STS-768c, see slide 8) frame. This OTM-0.3 based 40GE includes a 
RS(255,239) FEC, BER detection capabilities and fast-failure-detection and 
signalling mechanisms.





Mikael Abrahamsson <swmike@SWM.PP.SE>
04-04-2007 08:51
Please respond to Mikael Abrahamsson
 
        To:     STDS-802-3-HSSG@listserv.ieee.org
        cc: 
        Subject:        Re: [HSSG] 40G MAC Rate Discussion


On Tue, 3 Apr 2007, Shimon Muller wrote:

> Nothing magic about 40Gb for servers, just as there is nothing magic 
> about a 10x scaling factor, except for tradition. 40Gb happens to be in 
> the right ballpark for server needs in that timeframe, and it will be at 

> the right cost.

I represent a customer view here.

My coworkers who run servers seem to have no problem with link aggregation 

and they have a history with four port FE cards and they're now doing LAG 
with gig ports when they need it. The only 10GE attached servers we have 
exist in the network lab for cheap packet generation.

Myself, being a network engineer, I see operational problems with more 
than 4 links in a LAG but 4 is quite ok. I therefore see little reason for 

a 40G server speed, as this can be solved by 4*10GE LAG. A 10x scaling 
factor makes sense because 10 links in a LAG starts to create operational 
problems with proper load balancing, how you manage them both physically 
and logically, and a host of other problems that is better solved on the 
hardware layer.

I see more reason for a 40G optical standard that basically extends the 
OC192 10GE WAN PHY standard to OC768 as this would enable ethernet to be 
carried in current state of the art DWDM systems. This would of course be 
a moot point if we think that most DWDM vendors will have a 100GE DWDM 
transponder by the time the 100GE standard is ready, and a 40GE OC768 
compatible standard would take the same amount of time to implement as the 

100GE variant.

I do think that it should be taken into account that a 100GE standard will 

be carried over DWDM, and mechanisms should be implemented for 
fast-failure-detection, mostly of the "there is a one-way fiber 
break"-variant and the "the BER is high so the link is not good". This is 
perhaps something that should be discussed in another thread...

-- 
Mikael Abrahamsson    email: swmike@swm.pp.se