<InstrumentDescription xmlns:id="http://www.ieee.org/ATML/2008/02/InstrumentDescription" uuid="{5DC94F51-A6C8-4C6D-96B7-53EE62E5DD9F}" type="Instrument" xmlns="urn:P-IEEE-1671.2:2008.02:InstrumentDescription" xmlns:c="urn:IEEE-1671:2008.01:Common" xmlns:hc="urn:IEEE-1671:2008.01:HardwareCommon" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:P-IEEE-1671.2:2008.02:InstrumentDescription InstrumentDescription.xsd">
	<Description xmlns="urn:IEEE-1671:2008.01:Common">The DLM 3 kW and 4 kW Series programmable DC power supplies are designed to provide highly stable, continuously variable output voltage and current for a broad range of applications in a compact 2U ( 3½” high) chassis.</Description>
	<Identification xmlns="urn:IEEE-1671:2008.01:Common">
		<Version>1</Version>
		<ModelName>DLMRT488</ModelName>
		<Manufacturers>
			<Manufacturer name="Xantrex" cageCode="11111">
				<Contacts>
					<Contact name="Sales" email="sales@xantrex.com" phoneNumber="(800)446-6180"/>
				</Contacts>
				<FaxNumber>(800)925-5144</FaxNumber>
				<MailingAddress>
					<Address1>9250 Brown Deer Road </Address1>
					<City>San Diego</City>
					<State>CA</State>
					<Country>United States of America</Country>
					<PostalCode>92121</PostalCode>
				</MailingAddress>
				<URL>http://www.xantrex.com</URL>
			</Manufacturer>
		</Manufacturers>
	</Identification>
	<Interface xmlns="urn:IEEE-1671:2008.01:HardwareCommon">
		<Ports xmlns="urn:IEEE-1671:2008.01:Common">
			<Port name="V+" direction="Output"/>
			<Port name="V-" direction="Output"/>
			<Port name="DC_OUT" direction="Output"/>
		</Ports>
	</Interface>
	<Capabilities>
		<hc:Capability name="DC">
			<hc:Interface>
				<c:Ports>
					<c:Port name="DC"/>
				</c:Ports>
			</hc:Interface>
			<hc:SignalDescription>
				<Signal xmlns="STDBSC" xmlns:tsf716="STDTSFLib" xmlns:rt="ATMLDemoRTCASS" name="DC" Out="DC3">
					<rt:DC name="DC3" dc_ampl="30"/>
				</Signal>
			</hc:SignalDescription>
		</hc:Capability>
		<hc:CapabilityMap>
			<hc:Mapping>
				<hc:Map>
					<hc:Node>
						<hc:Path>
/InstrumentDescription/hc:Capabilities/hc:Capability[@name="DC"]/hc:Interface/c:Ports/c:Port[@name="DC"]
				</hc:Path>
					</hc:Node>
					<hc:Node>
						<hc:Path>/InstrumentDescription/hc:Interface/c:Ports/c:Port[@name="DC_OUT"]
				</hc:Path>
					</hc:Node>
				</hc:Map>
			</hc:Mapping>
		</hc:CapabilityMap>
	</Capabilities>
</InstrumentDescription>