Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[STDS-802-11-TGBN] Confict of bits in 11bn and 11bf in Figure 9-417―BSSID Information field format



Hi Abhi, Carol and all,

 

In CC50, when Same SMD and Ultra High Reliability are introduced in Figure 9-417―BSSID Information field format, B23 and B24 are used. Whilst in 11bf, B23 has already used B23.

For this figure, the use of reserved bits need to follow ANA database process, whilst neither of these bits have applied ANA, even for B21, used by 11be.

 

My suggestion would be 11bf use B23 for Sensing as the baseline, and 11bn use B24 and B25 for Same SMD and Ultra High Reliability. And Carol may update the ANA database accordingly. Your comments are welcome. And if possible, we need to update this figure ASAP.

 

 

 

 

regards

于健 Ross Jian Yu

Huawei Technologies

 


To unsubscribe from the STDS-802-11-TGBN list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBN&A=1