802.1 Maintenance Database
  • Home
  • Items
    • All
    • Open
    • Closed
    • For review
  • Status
  • Meetings
  • Help
Requested revision
Standard:IEEE 802.1AX-2008Clause:Appendix C.6
Clause title:dot3adAggPortActorOperKey
Rationale for revision
1. In Appendix C.6, MAX-ACCESS for OBJECT TYPE dot3adAggPortActorOperKey is defined as read-write.
Proposed text
1. Proper value for MAX-ACCESS for OBJECT TYPE dot3adAggPortActorOperKey should be read-only. 
   Check the description for the OBJECT and it is mentioned as read-only.
Impact on existing networks
Originator
Name:Ajith. Adapa Email:adapa.ajith@gmail.com
Affiliation:IPInfusion
Submitted:2013-10-03