Hi Ian, Thanks for your updating. Perhaps because I missed some offline discussions, I have some questions.
I sincerely hope to get some feedback. I am confused about this sentence “
The AMP Energizer shall support WPT waveform transmission.”. IMO, this sentence precludes AMP
energizers that only supports 2.4G excitation waveform transmission which may be inconsistent with the passed [Motion #81].
And if it is mandatory, why does the capability of supporting WPT transmission need to be defined?
•
IEEE 802.11bp defines at least the following capability parameters to be reported by the energizer to the AMP AP.
•
Whether or not support S1G WPT transmission
•
If supported, frequency related parameters for WPT. The frequency related parameters may include central frequency information, bandwidth information, etc.
•
Whether or not support 2.4G excitation waveform transmission.
•
Maximum Tx power.
•
Note: The energizer should
at least support one of the following transmissions: S1G WPT transmission or
2.4G excitation waveform transmission BR, Yingqiao Quan Communication Standards Devision
From: Ian Bajaj <0000340c29b22c99-dmarc-request@xxxxxxxxxxxxxxxxx>
Hi Sanket, and Yinan, I have accepted your proposed changes, and uploaded r7 to mentor: https://mentor.ieee.org/802.11/dcn/25/11-25-1357-07-00bp-pdt-wpt-energizer-control.docx Hi Bo, Please update the PDT SP as: Do you agree to incorporate the proposed draft text in document 11-25/1357r7 into the next version of the 11bp draft? Thanks and Regards Ian From: Sanket Kalamkar <sankal@xxxxxxxxxxxxxxxx>
Thanks for the updated PDT, Ian. Some comments/suggestions are marked in the attached document for you consideration. Best, Sanket Kalamkar From: Ian Bajaj <0000340c29b22c99-dmarc-request@xxxxxxxxxxxxxxxxx> WARNING:
This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros. Hi TTT members of Energizer Control, Please find the updated revision (r6) for the PDT uploaded to mentor. https://mentor.ieee.org/802.11/dcn/25/11-25-1357-06-00bp-pdt-wpt-energizer-control.docx Please reach out to me if there is any other feedback. Kind Regards Ian To unsubscribe from the STDS-802-11-TGBP list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBP&A=1
To unsubscribe from the STDS-802-11-TGBP list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBP&A=1
To unsubscribe from the STDS-802-11-TGBP list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBP&A=1 |